8300-AQM1 and 8300-AQM2 Handheld
Air Quality and Environmental Monitor
Indoor Air Quality Monitors
Models 8300-AQM1 and 8300-AQM2
(CO2, Temp, RH, and TVOC)
The Particles Plus® 8300-AQM1 and 8300-AQM2 Series Handheld Particle Counter and Environmental Monitor measures 0.3 to 25 µm particles with mass concentration and stores indoor air quality measurements of temperature, relative humidity, CO2, and TVOC in the 8300-AQM2. This instrument is the most versatile handheld Air Monitor available, with advanced power management and the industry’s first sleep mode, allowing for battery operation of periods that can exceed a month on a single charge. The AQM Series can be used as a stand-alone battery operated instrument or it can be easily integrated into a building automation and facility monitoring system via Ethernet, USB or (optional) Wireless 802.11 b/g, RS485 or RS232 connection.
The AQMs reports and displays 6 user-selectable particle size channels, as well as carbon dioxide (CO2), temperature, and relative humidity. The model 8300-AQM2 includes a PID Sensor for TVOC. The instrument monitors PM1, PM 2.5, PM5, PM 10 & TPM (and any other PM size value the user specifies) with an easy-to-use Channel Management control panel. The instrument also monitors flow, sensor status, date of last calibration, serial number, laser on-time, and date of manufacture for easy maintenance and warranty management.
User friendly field calibration for the integrated environmental sensors allows for single or dual point offsets, and ensures accuracy for air quality investigations. View data and generate environmental reports real-time on screen, via printer or USB key, or export to Particles Plus® Instrument Management Software. Particles Plus® instruments can be controlled and monitored remotely via web browser from any PC, tablet or smartphone supporting 20 concurrent user sessions.
The 8300-AQM1 and 8300-AQM2 store up to 45,000 time stamped particle count and environmental data records which provides data redundancy on every instrument. The AQMs mass concentration mode approximates density in µg/m³ and allows for density and refractive index corrections to ensure accuracy. All Particles Plus® counters meet ISO 21501-4 and JIS B9921. The 8300-AQM1 and 8300-AQM2 ensure compliance and accuracy with an on-board pulse height analyzer.
Measures 0.3 μm to 25 μm |
1.2 LPM flow rate |
Large easy-to-use icon driven color touch screen display |
Approximates mass concentration in μg/m³ and indicates simultaneous PM values |
Industry’s highest concentration of 30,000,000 particles/ft³ @ 10% coincidence |
User-selectable, adjustable particle channel sizes |
8300-AQM1 measures CO2, temperature and humidity. The 8300-AQM2 includes TVOC. |
Stores up to 45,000 sample records |
Connect using Ethernet, USB or (optional) Wireless 802.11 b/g, RS485 or RS232 |
Static or dynamic IP address (DHCP) connects to a local network or the Internet |
Seamless integration into a facility monitoring system with MODBUS RTU, ASCII or TCP |
Internet of Things JSON output allows for cloud based data storage and retrieval |
Included software permits remote operations, data management, diagnostics and more |
Displays and externally prints information with optional printer |
Internal audible alarm with user selectable thresholds for all environmental parameters |
Advanced power management for long battery operation and patented sleep mode |
Easy configuration and transferable from instrument to instrument |
User friendly field calibration with single or dual point offsets for all sensors |
Remote diagnostics allows for remote service investigation through the Internet |
User-selectable channel sizes |
Long life laser diode technology |
Lightweight high-impact injection molded plastic enclosure |
2 year limited warranty. Extended warranties available. |
Models | 8300-AQM1 and 8300-AQM2 |
Size Range | 0.3 to 25 μm |
Size Channels | Factory calibrated at 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm variable binning |
Flow Rate / Accuracy | 1.2 LPM |
Aerosol Concentration Range | 0.01 to 20,000 μg/m³ |
Concentration Limits | 30,000,000 particles/ft³ @ 10% coincidence |
Light Source | Long life laser diode |
Resolution | 0.0003 μg/m³ |
Zero Stability | No appreciable drift |
Count Modes | Real-Time Meter and graph, cumulative/differential count/m³ and count/ft³, and mass concentration (PM) |
Log Interval | Minimum 1 second with no hold time, maximum 99 hours |
Calibration | NIST traceable |
Display | 4.3" (10.9 cm) WQVGA (480x272) color touch screen |
Printer | (Optional) External thermal printer available |
Internal Vacuum Pump | Internal pump with automatic flow control |
Filtered Exhaust | Internal HEPA filter |
Number of Channels | 6 |
Custom Size Channels | Calibration for custom size channels available |
Audible Alarm | Adjustable built-in alarm |
Communication Modes | Ethernet, USB. (Optional) Wireless 802.11 b/g, RS485 or RS232. |
Environmental Sensors 8300-AQM1 | Includes NDIR CO2 (0-5000 ppm, resolution 1 ppm, accuracy ±1% FS, Response rate 20 seconds), temperature and relative humidity probe 32º to 122ºF (0º to 50ºC) ±1ºF (0.5ºC), 15-90% ±2% RH |
Environmental Sensors 8300-AQM2 | Includes all sensors in the 8300-AQM1 and TVOC PID (standard on the 8300-AQM2), 0-50 ppm / minimum detection level 5 ppb, accuracy ±1.5%, Response rate <3 seconds |
Alarm | Alarms on counts for all particle sizes, low battery, sensor failure, environmental sensors and flow |
Standards | ISO 21501-4 and JIS B9921 |
Instrument Calibration | Recommended minimum once per year. Gases, temperature and humidity sensors field calibratable. |
External Surface | Lightweight high-impact injection molded plastic enclosure |
Dimensions (L x W x H) | 6.33" x 4.25" x 12.26" (16.1 cm x 10.8 cm x 31.1 cm) includes handle and does not include probes |
Weight | 2.5 lb (1.1 kg) |
Accessories | Operating Manual and IMS Software on USB flash drive, isokinetic probe, temperature relative humidity sensor, filter, battery, USB cable, and power supply |
Optional Accessories | Calibration cap for gas sensor, carrying case, external printer, isokinetic probes, barb fittings, spare battery, external battery charger, printed manual, and IMS-RT monitoring system |
Data Storage | 45,000 sample records (rotating buffer) includes particle count data, environmental data, locations, times and annotations, scrollable on screen or printout |
Sample Time | 1 second to 99 hours |
Power | 110 to 240 VAC 50/60 Hz universal in-line power supply |
Operating Conditions | 41º to 104ºF (5º to 40ºC) / 20% to 95% non-condensing |
Storage Conditions | 32º to 122ºF (0º to 50ºC) / Up to 98% non-condensing |
Warranty | 2 year limited warranty. Extended warranties available. |
Handheld Carrying Case Part Number: AS-99015 | Wireless 802.11 b/g with Output Antenna Part Number: EE-80092 | Battery 55Wh Rechargeable & Removable Part Number: EE-80003A | External 55h Battery Charger (For EE-80003A) Part Number: AS-99005A |
Temperature and Humidity Probe Part Number: EE-80014A | Filter 0.1 CFM (2.83 LPM) Part Number: AS-99002 | Filter Assembly 0.1 CFM (2.83 LPM) Part Number: AS-99002A | RS-485/232 Connector (5 POS) Part Number: EE-79015A |
Isoprobe Threaded (Ni Plated Al) 0.1 CFM (2.83 LPM) Part Number: PS-12041 | Isoprobe Threaded (Stainless) 0.1 CFM (2.03 LPM) Part Number: PS-12070 | Isoprobe Barbed (Stainless) 0.1 CFM (2.83 LPM) Part Number: PS-12022 | Inlet Fitting Barbed 1/8 (Stainless) Part Number: PS-12005 |
External Thermal Printer Includes 2 Rolls of Paper Part Number: AS-99011 | Thermal Printer Paper Single Roll Part Number: AS-99012 | USB Cable 6ft (1.8m) Part Number: AS-99022 | Power Supply 15V ~2A 100-240 VAC Part Number: EE-80127 |
Power Supply Connector USA, Japan, Philippines, Taiwan Part Number: EE-80128 | Power Supply Connector Europe & Korea Part Number: EE-80129 | Power Supply Connector UK, Malaysia & Singapore Part Number. EE-80130 | Power Supply Connector China & Australia Part Number: EE-80131 |
Tubing (per foot) 3/8" OD (1/4" ID) Part Number: AS-99019 | Tubing (per foot) 3/8" OD (1/4" ID) Bev-A-Line XX Part Number: AS-99037 | IMS Software & User Manual (USB Key) Part Number: MN-24001 | 8000-AQM Series Validation Manual Part Number: MN-24002 |
8000-AQM Series User Manual (Printed) Part Number: MN-24001P |